ARC-101
ATM Rate and Media Converter
Installation and Operation Manual
Notice
This manual contains information that is proprietary to RAD Data Communications. No part of this
publication may be reproduced in any form whatsoever without prior written approval by RAD Data
Communications.
No representation or warranties for fitness for any purpose other than what is specifically mentioned in
this manual is made either by RAD Data Communications or its agents.
For further information contact RAD Data Communications at the address below or contact your local
distributor.
RAD data communications
Headquarters
12 Hanechoshet Street
Tel Aviv 69710 Israel
Tel: 972-3-6458181
Fax: 972-3-6498250
E-mail: rad@ rad.co.il
RAD data communications
US East
900 Corporate Drive
Mahwah, NJ 07430 USA
Tel: (201) 529-1100
Fax: (201) 529-5777
RAD data communications
US West
3631 South Harbor Boulevard
Suite 250
Santa Ana, CA 92704
Tel: (714) 850-0555
Fax: (714) 850-1555
© 1999 RAD Data Communications Publication No. 334-200-03/99
Vedere la pagina 0
1 2 3 4 5 6 ... 45 46

Sommario

Pagina 1 - ATM Rate and Media Converter

ARC-101ATM Rate and Media ConverterInstallation and Operation ManualNoticeThis manual contains information that is proprietary to RAD Data Communicati

Pagina 2

List of TablesivARC-101 Installation and Operation ManualList of TablesTable 1-1 Optical Module Characteristics...

Pagina 3 - Warranty

ARC-101 Features 1-1Chapter 1Introduction1.1 General DescriptionThe ARC-101, ATM Rate & Media Converter, provides transparent ATM rateand media

Pagina 4 - Telecommunication Safety

Chapter 1. IntroductionARC-101 Installation & Operation Manual1-2 ARC-101 Features1.2 ARC-101 FeaturesThis section provides a brief description

Pagina 5 - Regulatory Information

ARC-101 Installation & Operation Manual Chapter 1. IntroductionARC-101 Features 1-3TrafficManagementATM cells are transferred from one interface

Pagina 6 - Declaration of Conformity

Chapter 1. IntroductionARC-101 Installation & Operation Manual1-4 Specifications1.3 SpecificationsData RateUp to 155 MbpsIndicatorsPWRON when u

Pagina 7 - Contents

ARC-101 Installation & Operation Manual Chapter 1. IntroductionSpecifications 1-5OrderingARC-101/#ATM Rate Converter# Specify power supply:AC fo

Pagina 8 - CHAPTER 3 – OPERATION

Chapter 1. IntroductionARC-101 Installation & Operation Manual1-6 Specifications

Pagina 9 - List of Figures

Site Requirements 2-1Chapter 2InstallationThis chapter contains mechanical and electrical installation procedures forconnecting the ARC-101 to the mai

Pagina 10 - List of Tables

Chapter 2. InstallationARC-101 Installation & Operation Manual2-2 Rack Mounting Instructions2.3 Site RequirementsPowerThe ARC-101 is powered by

Pagina 11 - Introduction

ARC-101 Installation & Operation Manual Chapter 2. InstallationCable Connections 2-3Installation ofTwo UnitsRack adapter components for installi

Pagina 13 - Loopback Mode

Chapter 2. InstallationARC-101 Installation & Operation Manual2-4 Cable ConnectionsWhen the ARC-101 is used as a DCE or as a DTE, the RJ-45 pinou

Pagina 14 - 1.3 Specifications

ARC-101 Installation & Operation Manual Chapter 2. InstallationARC-101 Modules 2-5AC PowerConnectionThe ARC-101's power connector is locate

Pagina 15 - Ordering

Chapter 2. InstallationARC-101 Installation & Operation Manual2-6 ARC-101 Modules2.6 ARC-101 ModulesModuleCharacteristicsSC13M/155 Module Figu

Pagina 16 - 1-6 Specifications

ARC-101 Installation & Operation Manual Chapter 2. InstallationARC-101 Modules 2-7ST13L/155 Module Figure 2-10 ST13L/155 Module Front PanelWave

Pagina 17 - Installation

Chapter 2. InstallationARC-101 Installation & Operation Manual2-8 ARC-101 ModulesUTP/155 Module Figure 2-12 UTP/155 Module Front PanelConnector:

Pagina 18 - Site Requirements

ARC-101 Installation & Operation Manual Chapter 2. InstallationARC-101 Modules 2-9E3 Module Figure 2-13 E3 Module Front PanelConnector: BNCUsed

Pagina 19 - 2.5 Cable Connections

Chapter 2. InstallationARC-101 Installation & Operation Manual2-10 ARC-101 ModulesE1 and E1/LTUModulesThe E1 link interface (Coax/UTP), as well a

Pagina 20 - 2-4 Cable Connections

ARC-101 Installation & Operation Manual Chapter 2. InstallationARC-101 Modules 2-11Inserting andRemovingModulesInserting ModulesTo insert a modu

Pagina 21 - Grounding

Chapter 2. InstallationARC-101 Installation & Operation Manual2-12 ARC-101 ModulesJumper Settingsfor E1 and E1/LTUThe jumpers JP5, JP6, JP10, JP1

Pagina 22 - 2.6 ARC-101 Modules

ARC-101 Installation & Operation Manual Chapter 2. InstallationARC-101 Modules 2-13Jumper Settingsfor T3 Figure 2-17 T3 Jumper LocationsThe jum

Pagina 23 - ARC-101 Modules 2-7

WarrantyThis RAD product is warranted against defects in material and workmanship for a period of one yearfrom date of shipment. During the warranty p

Pagina 24 - 2-8 ARC-101 Modules

Chapter 2. InstallationARC-101 Installation & Operation Manual2-14 ARC-101 Modules

Pagina 25 - ARC-101 Modules 2-9

Operating Procedure 3-1Chapter 3OperationThe ARC-101 has several LED indicators, providing information on theARC-101's general status, as well as

Pagina 26 - 2-10 ARC-101 Modules

Chapter 3. OperationARC-101 Installation & Operation Manual3-2 Operating Procedure3.1 Operating ProcedureNoteThe interface modules are not hot-

Pagina 27 - Removing

ARC-101 Installation & Operation Manual Chapter 3. OperationOperating Procedure 3-3 Figure 3-2 ARC-101 Block Diagram

Pagina 28 - Jumper Settings

Chapter 3. OperationARC-101 Installation & Operation Manual3-4 Operating Procedure

Pagina 29

Accessing, Using and Exiting Monitor Mode 4-1Chapter 4Software Management4.1 IntroductionMonitor mode enables software management of the ARC-101. Fo

Pagina 30 - 2-14 ARC-101 Modules

Chapter 4. Software ManagementARC-101 Installation & Operation Manual4-2 Configuration Window4.3 Screen ExplanationsEach of the screens shown b

Pagina 31 - Operation

ARC-101 Installation & Operation Manual Chapter 4. Software ManagementConfiguration Window 4-3To Save the Configuration:CONFIGURATION1. System P

Pagina 32 - 3.1 Operating Procedure

Chapter 4. Software ManagementARC-101 Installation & Operation Manual4-4 Configuration WindowThe options are 25%, 50%, 75%, 90% and 100%.EFCI Mar

Pagina 33 - Operating Procedure 3-3

ARC-101 Installation & Operation Manual Chapter 4. Software ManagementConfiguration Window 4-5Loopback State(Default - Disable); options: Disabl

Pagina 34 - 3-4 Operating Procedure

Safety WarningsThe exclamation point within a triangle is intended to warn the operator orservice personnel of operation and maintenance factors relat

Pagina 35 - Software Management

Chapter 4. Software ManagementARC-101 Installation & Operation Manual4-6 Performance Monitoring Window4.6 Diagnostics WindowThe ARC-101 can be

Pagina 36 - 4.5 Configuration Window

ARC-101 Installation & Operation Manual Chapter 4. Software ManagementPerformance Monitoring Window 4-7• Link Status• ATM StatusPERFORMANCE MONI

Pagina 37 - Parameters

Chapter 4. Software ManagementARC-101 Installation & Operation Manual4-8 Performance Monitoring WindowSONET/SDH Link Status WindowLOS Loss of Sig

Pagina 38 - Configuration

ARC-101 Installation & Operation Manual Chapter 4. Software ManagementPerformance Monitoring Window 4-9T3 Link Status Window - Errors/Alarms dis

Pagina 39 - ASCII Terminal

Chapter 4. Software ManagementARC-101 Installation & Operation Manual4-10 Performance Monitoring WindowE3 Link Status WindowLOS Loss of SignalOOF

Pagina 40 - 4.6 Diagnostics Window

ARC-101 Installation & Operation Manual Chapter 4. Software ManagementPerformance Monitoring Window 4-11NoteThe Cells Transmitted counter is not

Pagina 41 - Link Status

Chapter 4. Software ManagementARC-101 Installation & Operation Manual4-12 Performance Monitoring Window

Pagina 42

Regulatory InformationFCC-15 User InformationThis equipment has been tested and found to comply with the limits of the Class A digital device,pursuant

Pagina 43

Declaration of ConformityManufacturer’s Name: RAD Data Communications Ltd.Manufacturer’s Address: 12 Hanechoshet St.Tel Aviv 69710Israeldeclares that

Pagina 44 - Monitoring

ARC-101 Installation and Operation Manual iContentsCHAPTER 1 – INTRODUCTION1.1 General Description...

Pagina 45

ContentsiiARC-101 Installation and Operation ManualJumper Settings for E1 and E1/LTU.....

Pagina 46

ARC-101 Installation and Operation Manual iiiList of Figures Figure 1-1 ARC-101 Rate Conversion Application ...........

Commenti su questo manuale