Chapter 7 Fault Management IPmux-8/16 User’s Manual
7-4 Monitoring Object Status
Viewing the History Log
The History Log command enables you to display a history of alarms (up to
512 entries) that were sent from the selected IPmux to the network management
station.
To view the History Log:
Fault > History Log > List…
The System Log Buffer table appears.
Figure 7-3. System Log Buffer
Table 7-3. System Log Buffer Parameters
Parameter Possible Values / Remarks
No. The number of the trap in the Log Buffer
Description Brief description of the trap – up to 80 characters
[Next] Displays next 20 entries in table
[Print…] Prints list
[Start From] Opens Start From dialog box. Select starting Interval Number and click <Set>
[Save to File…] Saves list