Installation and Operation Manual Chapter 7 Application Tutorial
Egate-100 Ver. 4.0 WiMAX Backhauling Opposite RICi-4T1 7-51
Egate-100
Main Menu> Configuration> Physical Layer> T3> T1
1. Port Number [57-84] ... (77)
2. Administrative Status > (Up)
3. Frame Type > (D4)
4. Idle code[0 – ff] ...(0)
5. Alarms > (Unmasked)
Please select item <1 to 5>
F - Forward Port; B - Backward Port; S - Save
ESC-prev.menu; !-main menu; &-exit
Figure
7-70. Configuring T1 Ports for RICi-4T1 (C)
³ To configure the T1 ports for RICi-4T1 (D):
1. In the Physical Port T3 menu, select T3 port 3, and then navigate to the
Physical Port T1 menu by selecting T1. (It is not necessary to configure
T3 port 3, as it was already configured in the procedure for RICi-4T1 (C).)
2. In the Physical Port T1 menu, configure T1 port 81 as illustrated in
Figure
7-71
.
3. Repeat the same configuration for T1 ports 82 to 84.
Egate-100
Main Menu> Configuration> Physical Layer> T3> T1
1. Port Number [57-84] ... (81)
2. Administrative Status > (Up)
3. Frame Type > (D4)
4. Idle code[0 – ff] ...(0)
5. Alarms > (Unmasked)
Please select item <1 to 5>
F - Forward Port; B - Backward Port; S - Save
ESC-prev.menu; !-main menu; &-exit
Figure
7-71. Configuring T1 Ports for RICi-4T1 (D)
Setting Logical Layer Parameters
You must configure logical ports for the T1 ports, as specified in
Table
7-11
. You
must configure the following logical ports:
For RICi-4T1 (A): Logical ports 22 – 25 with PPP over HDLC, which are then
bound to logical port 120 with MLPPP protocol.
For RICi-4T1 (B): Logical ports 53 – 56 with PPP over HDLC, which are then
bound to logical port 121 with MLPPP protocol.