Installation and Operation Manual Appendix D IR-IP Interface Module
ASM-40 Ver. 1.0 Performing Preliminary Configuration D-9
The ERR indicator must turn off.
At this stage, the communication with IR-IP router is lost, because its IP address
has been changed. Therefore, you must reconfigure the destination IP address of
the Telnet host. If you wish, you may also change the temporary IP address
assigned to the host (192.168.205.2) back to its permanent address.
After changing the destination IP address of the Telnet host, it is recommended
to turn ASM-40 off for a few seconds and then back on, before continuing the
configuration of the IP router in accordance with the
Quick Setup Menu
section
below. At this time, in Step 2 the ERR indicator turns off after the 15-second
interval.
Changing the LAN IP Address of a Configured IR-IP
The LAN IP address of an already-configured IR-IP can be changed while it
operates, this means it is not necessary to turn ASM-40 off before starting the
configuration procedure. Note however that the IP traffic flow through IR-IP will
be disrupted until the other stations in the IP network learn the new address.
To change the LAN IP address of an already-configured IR-IP, use the procedure
described above for a new IR-IP with the following differences:
1. Configure the destination address of the
ping
utility to the new LAN interface
IP address. It is not necessary to change the Telnet host source address.
2. When ready, set section 1 of the IR-IP DIP switch to ON.
The ERR indicator starts flashing faster (approximately four times a
second).
3. Perform Steps 4, 5 of the procedure used for a new IR-IP.
What to Do If ...
The INT indicator does not light immediately after ASM-40 is turned on
The IR-IP interface module does not receive power from the ASM-40 power
supply. Service is required.
After the power-up process ends, the INT indicator shows LAN integrity. It may
stay turned off without indicating power supply failure.
The ERR indicator does not light immediately after ASM-40 is turned on
IR-IP is faulty and must be replaced.
After turn-on, the ERR indicator lights for 15 seconds and then turns off. ACT
does not light, and there is no response from IR-IP
No software loaded into IR-IP. Download software using the procedure described
in the
New Software Download Menu
section below.
After turn-on, the ERR indicator lights for 15 seconds, and then turns off. ACT
lights from time to time, but there is no response from IR-IP
IR-IP has been configured. If you do not know the current IP address of the LAN
interface, erase IR-IP router configuration using the procedure given in the
Erasing User’s Configuration
section below.