RAD Data comm Optimux-106 Specifiche Pagina 100

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 99
Appendix A Pinouts Installation and Operation Manual
A-2 Alarm Connector Optimux-106 Ver. 6.1
A.3 Alarm Connector
The Optimux-106 ALARM connector is a 9-pin female connector, which includes
the contacts of the major and minor alarm relays.
Figure
A-1
shows the pin
functions. The relay positions are shown in the non-energized (alarm active)
state.
ALARM
CONNECTOR
MINOR
ALARM
RELAY
MAJOR
ALARM
RELAY
1
3
2
4
6
5
Figure
A-1. ALARM Connector Wiring