Installation and Operation Manual Chapter 1 Introduction
Optimux-34 Ver. 2.81 Technical Specifications 1-9
Figure
1-8. External and Loopback Timing
Power Requirements
Optimux-34 has a hot-swappable, wide range, universal power supply for AC and
DC options.
A second power supply is optionally installed in the Optimux-34 to assure
continuous operation in case of supply failure. When the two supplies are turned
ON, they share the power consumption of the unit. If one of the power supplies
fails, the other provides the full power consumption.
1.4 Technical Specifications
Electrical Link
Interface (E3)
Electrical Interface
According to ITU-T Rec. G.751
Jitter
According to ITU-T Rec. G.823
Data Rate
34,368 kbps
Line Code
HDB3
Impedance
75Ω unbalanced
Range
According to ITU-T Rec. G.703
Connectors (2)
SMB-BNC
Redundancy
Additional electrical link is optional