Chapter 4 Configuration Installation and Operation Manual
4-12 Configuring for Operation RICi-E3, RICi-T3 Ver. 1.0
To configure the Ethernet port:
1. From the Physical Ports menu, select Ethernet.
The Ethernet menu appears as illustrated in
Figure 4-9
.
RICi-E3, RICi-T3
Configuration > Physical Ports > Ethernet
1. Administrative Status (Up)
2. Auto-Negotiation (Enable)
3. Flow Control (Enable)
4. Max Capability Advertised (100base - TX Full Duplex)
5. MDIX Auto cross over (Enable)
>
ESC-prev menu; !-main menu; &-exit 1 user(s)
Figure 4-9. Ethernet Menu
2. In the Ethernet menu, configure the following:
Administrative Status
Up – the network port is enabled
Down – the network port is disabled.
Autonegotiation
Enable – autonegotiation is enabled
Disable – autonegotiation is disabled
Flow Control
Enable – flow control is enabled
Disable – flow control is disabled.
Max Capability Advertised. The highest traffic handling capability to be
advertised during the autonegotiation process
10baseT Half Duplex
10baseT Full Duplex
100baseTX Half Duplex
100baseTX Full Duplex.
MDIX Auto cross over
Enable – MDIX Auto cross over is enabled
Disable – MDIX Auto cross over is disabled.
3. Select Save to complete the network Ethernet port configuration.